Most pool filter problems announce themselves through the pressure gauge, through weak flow at the returns, or through water that will not clear. This guide works by symptom, from the simplest checks to the ones that usually need a professional.

Start with your clean baseline

There is no single “correct” filter pressure. Different filters, pumps and plumbing produce different readings, and a variable-speed pump will show lower pressure at lower speeds. What matters is how today’s reading compares with your own clean baseline, the pressure right after you cleaned or backwashed the filter with the pump at its normal speed.

  • Write the baseline down, or mark it on the gauge with tape or a marker.
  • A rise of roughly 8 to 10 psi above that baseline is the common signal to clean or backwash.
  • If you work in kilopascals, 1 psi is about 6.9 kPa, so 8 to 10 psi is roughly 55 to 69 kPa.
  • Typical clean readings vary a lot, often somewhere in the range of 10 to 25 psi, so check your filter’s manual rather than copying someone else’s number.

Gauges themselves fail. If the reading seems impossible, or does not match the strength of flow at the returns, the gauge may be the problem.

High pressure

High pressure usually means water is struggling to get through the filter or back out to the pool. Check:

  • A dirty filter. Clean the cartridge (how to clean a cartridge filter) or backwash a sand or DE filter.
  • Closed or partly closed valves on the return side.
  • A clogged return line or return fitting.
  • A pump that is too big for the filter or plumbing, pushing more flow than the system can handle. See what size pool pump you need.
  • Pressure that returns quickly after cleaning. The sand may be worn or channeled, a cartridge may be oil-fouled or worn, or DE grids may be coated in oils or scale.

Is 15 psi too high? It depends on the baseline. If your clean reading is around 8 psi, then 15 means it is time to clean. If your clean reading is 14 or 15, it is normal. As a general guide, a pressure that is rising steadily above your own baseline is the thing to act on.

Low pressure and weak flow

Low pressure with weak flow usually points to the suction side: the pump is not getting enough water to push through the filter. A dirty filter normally causes high pressure, not low. Work through these in order:

  1. Water level. The water should sit around the middle of the skimmer opening. If it is too low, the skimmer pulls air.
  2. Skimmer and pump baskets. Empty both. Leaves, seed pods and skimmer socks can restrict flow.
  3. Valves. Make sure suction valves are open and in their normal positions.
  4. Pump lid and O-ring. A dry, dirty or cracked O-ring lets air in. Clean the O-ring, lubricate it with a pool-safe silicone lubricant and re-seat the lid.
  5. Lost prime. Refill the pump basket with water per your manual and restart.
  6. Clogged impeller. If baskets are clean but flow is poor, debris may be lodged in the impeller. Turn off power at the breaker before opening the pump.
  7. Blocked suction line. If one suction line is weak and another works well, a line may be partially blocked. This is often a job for a professional.
  8. Bad gauge. If the returns look strong but the gauge reads low, replace the gauge.

Above-ground pools. Smaller above-ground systems follow the same rules, and Intex owners can also work through why an Intex pool pump is not pumping. Check the strainer valves or plugs where the hoses connect to the pool, any clogged skimmer or strainer basket, kinked hoses, and a cartridge that is clogged or worn. Many above-ground filters also lose flow when a hose connection is loose and sucks in air.

Variable-speed pumps. At low RPM, lower pressure is normal. Compare today’s reading with the same speed on a day when the pool was running well.

Pressure reads zero

Why would a filter read 0 psi?

  • The pump is off, or has lost prime. If the pump is running but nothing is moving, check the basket for water and for air.
  • A closed valve is stopping water from reaching the filter.
  • A failed gauge. Try tapping it gently, or replace it. A new gauge is inexpensive.
  • A clogged gauge port or stuck needle.
  • A major blockage upstream of the filter.

If the pump hums but nothing moves, switch it off and see the “Filter or pump will not turn on” section below.

Air in the system

Air in the filter or pump is almost always an air leak on the suction side or a pump that has not primed properly. Signs include:

  • Bubbles in the pump basket or at the return jets.
  • Spitting or gurgling at the returns.
  • A pump basket that never fills or a pump that makes a rumbling sound.
  • A filter that does not fill with water.

Check, in order:

  • Water level in the pool.
  • The skimmer weir (the small flap) is not jammed.
  • The pump lid and its O-ring.
  • The pump basket drain plug and its O-ring.
  • Unions, valve stems and fittings on the suction line.
  • Cracks in the pump housing or lid.

If you cannot find the source, some technicians trace leaks by running shaving cream over joints while the pump runs, since an air leak draws it in and leaves a dimple. A professional can pressure-test lines.

What is an air relief valve?

An air relief valve, also called a bleeder, is a small valve at the top of most filters. Use it to:

  • Release pressure before opening the tank. Turn the pump off first, then open the valve until pressure falls and the gauge reads zero.
  • Bleed trapped air after reassembling the filter. Start the pump and open the valve slightly until a steady stream of water, not air, comes out, then close it.

Stand to the side when you start the pump or open a pressurized filter, and keep your face away from the valve and lid.

Filter or pump will not turn on

If nothing happens:

  • Check the breaker, GFCI outlet (for plug-in above-ground pumps) and the timer settings.
  • If the motor hums but does not start, a clogged impeller, a seized motor shaft or a failed capacitor are common causes. Turn power off before inspecting anything.
  • If the pump runs and then shuts off, overheating is likely. Check ventilation, direct sun exposure and airflow around the motor, and check that power wiring is correct.

Capacitors can hold a charge even when the power is off, and voltage faults can be dangerous. Leave electrical diagnosis to a licensed electrician or pool technician. See how to wire a pool pump for more on why pool electrical work needs care.

Cloudy water with normal pressure

If pressure looks normal and the water is still cloudy, the cause may not be the filter’s cleanliness at all:

  • A torn cartridge or damaged DE grids can let dirt through.
  • Worn sand or a cracked lateral can fail to filter or send sand into the pool.
  • Insufficient run time leaves the water under-filtered. See how long a pool pump should run.
  • Water chemistry problems can cloud water no matter how well the filter works.

Should the filter always be on?

No. Most pools do not need the pump running 24 hours a day. The goal is enough running time to turn over the pool’s water at least once a day and to circulate sanitizer. Special cases, such as treating algae or protecting equipment from freezing, can justify running longer. The run-time article explains how to work out a sensible schedule.

Safety and when to call a pro

  • Turn off power at the breaker before opening a pump or motor.
  • Release pressure with the air relief valve before opening a filter tank.
  • Do not run the pump dry for experiments. It can damage the shaft seal.
  • Call a professional if the pump will not prime, the breaker trips, the motor overheats, you smell burning, you suspect underground plumbing damage, or the same problem comes back right after you fix it.

If the problem turns out to be a worn-out pump, see replacing a pool pump. If the filter itself is at end of life, see how long a pool filter lasts.

The complete guide to pumps and filters